RESUMO
In 2014, external quality assessment trials for urinalysis and faecal occult blood (FOB) were performed of 1,270 participants. Urine chemistry and FOB tests were evaluated three times, while urine sediment examination by photography was evaluated one time. Urine chemistry tests consisted of pH, protein, glucose, ketone, bilirubin, blood, urobilinogen, nitrite, leukocyte, and specific gravity (SG). The urine chemistry test results showed accuracy rates >95%, while those of the SG test by using a refractometer had accuracy rates <95%. In the FOB quality test, the Bio Focus reagent (BIO FOCUS Co., Korea) disclosed low positive rates (87%). The result of the FOB quantity test showed different values according to the instruments used, and the Kyowa instrument (Kyowa Chemical Industry Co., Japan) revealed the lowest values. In a urinary sediment examination, it is necessary to increase the frequency of the quality assessment trials due to low accuracy rates.
Assuntos
Bilirrubina , Indústria Química , Química , Glucose , Concentração de Íons de Hidrogênio , Coreia (Geográfico) , Leucócitos , Sangue Oculto , Fotografação , Gravidade Específica , Urinálise , UrobilinogênioRESUMO
Six trials with 3 samples for each trial for external quality assessment of general chemistry and blood gas were performed in 2009. All the control materials were sent in specifically-made boxes at the same time. The response rates were 87.5% in general chemistry and 89.3% in blood gas. The items included sodium, potassium, chloride, BUN, glucose, calcium, phosphorus, uric acid, creatinine, bilirubin, total protein, albumin, total cholesterol, triglyceride, AST, ALT, ALP, LD and GGT in general chemistry and pH, pCO2 and pO2 in blood gas. Compared with the previous year (2008), change of the methods of analysis was not remarkable. The peer group coefficient of variation and the VIS scores of general chemistry items were slightly improved.
Assuntos
Bilirrubina , Cálcio , Química Clínica , Colesterol , Creatinina , Glucose , Concentração de Íons de Hidrogênio , Coreia (Geográfico) , Grupo Associado , Fósforo , Potássio , Sódio , Ácido ÚricoRESUMO
Three external quality assesment trials which composed of 16 control materials(12 chemical materials and four sets of microscopic photograph of urinary sediment) for interlaboratory quality control assesment in urinalysis were performed with 796, 823, and 841 participants, in each, in the year of 2009. The response rate were 97.1% (796/820), 95.5% (823/862) and 97.1% (841/866), in the first, the second and the third trials, in each. The test items include pH, glucose, protein, ketone, bilirubin, blood, urobilinogen, nitrite, leukocyte estrase, specific gravity and four microscopic photographs of urinary sediment. The survey results are summarized as follows: 1. The chemical quality control test in urinalysis revealed generally good concordance. 2. The percentage of using urinalysis analyzer was slightly decreased as 82.3% and the distribution of using reagent strip was similar to the previous year. 3. The percentage of response rate of microscopic photographs of urinary sediment was 83.5% (702/841) and the percentage of good performance of these tests ware 83.6% to 99.1%.
Assuntos
Bilirrubina , Equidae , Glucose , Concentração de Íons de Hidrogênio , Coreia (Geográfico) , Leucócitos , Controle de Qualidade , Fitas Reagentes , Gravidade Específica , Urinálise , UrobilinogênioRESUMO
Six trials with 3 samples for each trial for external quality assessment of general chemistry and blood gas were performed in 2008. All the control materials were sent in specifically-made boxes at the same time. The response rates were 93.5% in general chemistry and 88.1% in blood gas. The items included sodium, potassium, chloride, BUN, glucose, calcium, phosphorus, uric acid, creatinine, bilirubin, total protein, albumin, total cholesterol, triglyceride, AST, ALT, ALP, LD and GGT in general chemistry and pH, pCO2 and pO2 in blood gas. Compared with the previous year (2007), change of the methods of analysis and the peer group coefficient of variation was not remarkable and the VIS scores of general chemistry items were slightly improved.
Assuntos
Bilirrubina , Cálcio , Química Clínica , Colesterol , Creatinina , Glucose , Concentração de Íons de Hidrogênio , Coreia (Geográfico) , Grupo Associado , Fósforo , Potássio , Sódio , Ácido ÚricoRESUMO
Three external quality assesment trials which composed of 16 control materials (12 chemical materials and four sets of microscopic photograph of urinary sediment) for interlaboratory quality control assesment in urinalysis were performed with 699, 718, and 732 participants, in each, in the year of 2008. The response rate were 95.4% (699/733), 96.6% (718/743) and 95.3% (732/767), in the first, the second and the third trials, in each. The test items include pH, glucose, protein, ketone, bilirubin, blood, urobilinogen, nitrite, leukocyte estrase, specific gravity and four microscopic photographs of urinary sediment. The survey results are summarized as follows: 1. The chemical quality control test in urinalysis revealed generally good concordance. 2. The percentage of using urinalysis analyzer was slightly decreased as 83.0% and the distribution of using reagent strip was similar to the previous year. 3. The percentage of response rate of microscopic photographs of urinary sediment was 81.3% (571/732) and the percentage of good performance of these tests ware 32.9% to 80.5%.
Assuntos
Bilirrubina , Equidae , Glucose , Concentração de Íons de Hidrogênio , Coreia (Geográfico) , Leucócitos , Controle de Qualidade , Fitas Reagentes , Gravidade Específica , Urinálise , UrobilinogênioRESUMO
OBJECTIVES: This study was conducted to determine the reference interval of serum thyroid hormones (TSH, FT(3), FT(4)) in healthy Korean adults. METHODS: Health examination data from 1,591 healthy Korean adults who visited an university hospital were analyzed. Patients with specific health conditions capable of altering laboratory results were excluded from the study. Serum thyroid hormones were measured using IMMULITE 2000 (DPC, USA, 2002). Subjects were 18-65 years old; 911 were male, and 690 were female. RESULTS: The arithmetic means of TSH, FT(3), and FT(4) values for male subjects were 1.28+/-1.84 micronIU/ml, 3.23+/-0.57 pg/ml, and 1.42+/-0.22 ng/dl, respectively. In female subjects, the arithmetic means of TSH, FT3, and FT4 values were 1.49+/-2.08 micronIU/ml, 3.08+/-0.54 pg/ml, and 1.29 +/-0.24 ng/dl, respectively. The arithmetic mean FT(4) value for males decreased with age (p<0.01). The arithmetic mean FT(3) value for females increased with age (p<0.01). The arithmetic mean thyroid hormone values of all study subjects differed significantly based on season. The arithmetic mean of male FT(4) decreased with increasing BMI (p<0.01). The arithmetic mean of female FT(3) increased with increasing BMI (p<0.01). The reference intervals recommended by the IMMULITE 2000 manufacturer are 0.40-4.00 micronIU/ml for TSH, 1.80-4.20 pg/ml for FT(3), and 0.80-1.90 ng/dl for FT(4) (same values for both genders). CONCLUSIONS: There was a significant difference in the interval of thyroid hormones between males and females, but the reference interval of IMMULITE 2000 was not established by gender. There is a need to reestablish the reference interval for thyroid hormones in Korean healthy adults.
Assuntos
Adolescente , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Índice de Massa Corporal , Coreia (Geográfico)/epidemiologia , Valores de Referência , Fatores Sexuais , Fatores Socioeconômicos , Tireotropina/sangue , Tiroxina/sangue , Tri-Iodotironina/sangueRESUMO
Three external quality assesment trials which composed of 16 control materials (12 chemical materials and four microscopic photographs of urinary sediment) for interlaboratory quality control assesment in urinalysis were performed with 638, 645, and 662 participants, in each, in the year of 2007. The response rate were 95.5% (638/668), 96.7% (645/667) and 97.1% (662/682), in the first, the second and the third trials, in each. The test items include pH, glucose, protein, ketone, bilirubin, blood, urobilinogen, nitrite, leukocyte esterase, specific gravity and four microscopic photographs of body fluid and urinary sediment. The survey results are summarized as follows: 1. The chemical quality control test in urinalysis revealed generally good concordance. 2. The percentage of using urinalysis analyzer was slightly increased as 87.5% and the distribution of using reagent strip was similar to the previous year. 3. The percentage of response rate of microscopic photographs of urinary sediment was 80.7% (536/662) and the percentage of good performance of these tests was 60.6% to 99.1%.
Assuntos
Bilirrubina , Líquidos Corporais , Hidrolases de Éster Carboxílico , Equidae , Glucose , Concentração de Íons de Hidrogênio , Coreia (Geográfico) , Leucócitos , Controle de Qualidade , Fitas Reagentes , Gravidade Específica , Urinálise , UrobilinogênioRESUMO
Three external quality assesment trials which composed of 16 control materials (12 chemical materials and four microscopic photographs of urinary sediment) for interlaboratory quality control assesment in urinalysis were performed with 638, 645, and 662 participants, in each, in the year of 2007. The response rate were 95.5% (638/668), 96.7% (645/667) and 97.1% (662/682), in the first, the second and the third trials, in each. The test items include pH, glucose, protein, ketone, bilirubin, blood, urobilinogen, nitrite, leukocyte esterase, specific gravity and four microscopic photographs of body fluid and urinary sediment. The survey results are summarized as follows: 1. The chemical quality control test in urinalysis revealed generally good concordance. 2. The percentage of using urinalysis analyzer was slightly increased as 87.5% and the distribution of using reagent strip was similar to the previous year. 3. The percentage of response rate of microscopic photographs of urinary sediment was 80.7% (536/662) and the percentage of good performance of these tests was 60.6% to 99.1%.
Assuntos
Bilirrubina , Líquidos Corporais , Hidrolases de Éster Carboxílico , Equidae , Glucose , Concentração de Íons de Hidrogênio , Coreia (Geográfico) , Leucócitos , Controle de Qualidade , Fitas Reagentes , Gravidade Específica , Urinálise , UrobilinogênioRESUMO
Six trials with 3 samples for each of external quality assessment for general chemistry and blood gas were performed in 2007. All the control materials were sent in specifically-made boxes at the same time. The response rates were 92.0% in general chemistry and 95.5% in blood gas. The items included sodium, potassium, chloride, BUN, glucose, calcium, phosphorus, uric acid, creatinine, bilirubin, total protein, albumin, total cholesterol, triglyceride, AST, ALT, ALP, LD and GGT in general chemistry and pH, pCO2 and pO2 in blood gas. Compared with the previous year (2006), the methods of analysis were slightly changed and the coefficient of variation and VIS scores of general chemistry items were not significantly changed.
Assuntos
Bilirrubina , Cálcio , Química Clínica , Colesterol , Creatinina , Glucose , Concentração de Íons de Hidrogênio , Coreia (Geográfico) , Fósforo , Potássio , Sódio , Ácido ÚricoRESUMO
According to the World Health Organization (WHO) classification system, cases with t(8;21)(q22;q22) should be diagnosed as acute myeloid leukemia (AML) even with a blast count of less than 20 percent in blood or bone marrow. It is an uncommon manifestation, moreover hypocellularity is rarely observed in this subtype of leukemia. Here, we report a case of t(8;21) in a patient with marked hypocellularity of less than 5 percent and a blast count of less than 20 percent. This patient responded relatively well to chemotherapy. An allogeneic bone marrow transplantation was performed with good engraftment . This case suggests that hypocellular AML with a t(8;21) has as good a prognosis as hypercellular AML with t(8;21).
Assuntos
Humanos , Medula Óssea , Transplante de Medula Óssea , Classificação , Tratamento Farmacológico , Leucemia , Leucemia Mieloide Aguda , Prognóstico , Organização Mundial da SaúdeRESUMO
Ten trials of external quality assessment for Clinical Chemistry in general chemistry and blood gas were performed in 2005. All the control materials were sent in specifically-made boxes at the same time. The response rates were 90.1% in general chemistry and 84.8% in blood gas. The items included sodium, potassium, chloride, BUN, glucose, calcium, phosphorus, uric acid, creatinine, bilirubin, total protein, albumin, total cholesterol, triglyceride, AST, ALT, ALP, LD and GGT in general chemistry and pH, pCO2 and pO2 in blood gas. Compared with the previous year (2004), the methods of analysis were changed and the coefficient of variation and VIS scores of general chemistry items were increased.
Assuntos
Bilirrubina , Cálcio , Química , Química Clínica , Colesterol , Creatinina , Glucose , Concentração de Íons de Hidrogênio , Coreia (Geográfico) , Fósforo , Potássio , Sódio , Triglicerídeos , Ácido ÚricoRESUMO
Three external quality assesment trials which composed of 16 control materials (12 chemical materials and four microscopic photographs of urinary sediment) for interlaboratory quality control assesment in urinalysis were performed with 451, 452, and 476 participants, in each, in the year of 2005. The response rate were 95.6% (451/472), 91.9% (452/492) and 95.6% (476/498), in the first , the second and the third trials, in each. The test items include pH, glucose, protein, ketone, bilirubin, blood, urobilinogen, nitrite, leukocyte estrase, specific gravity and four microscopic photographs of urinary sediment. The survey results are summarized as follows: 1. The chemical quality control test in urinalysis revealed generally good concordance. 2. The percentage of using urinalysis analyzer was slightly increased as 91.2% and the distribution of using reagent strip was similar to the previous year. 3. The percentage of response rate of microscopic photographs of urinary sediment was 76.5%(387/498) and the percentage of good performance of these tests ware 63.6% to 86.5%.
Assuntos
Bilirrubina , Equidae , Glucose , Concentração de Íons de Hidrogênio , Coreia (Geográfico) , Leucócitos , Controle de Qualidade , Fitas Reagentes , Gravidade Específica , Urinálise , UrobilinogênioRESUMO
Ten trials of external quality assessment for Clinical Chemistry in general chemistry and blood gas were performed in 2004. All the control materials were sent in specifically-made boxes at the same time. The response rates were 92.0% in general chemistry and 86.0% in blood gas. The items included sodium, potassium, chloride, BUN, glucose, calcium, phosphorus, uric acid, creatinine, bilirubin, total protein, albumin, total cholesterol, triglyceride, AST, ALT, ALP, LD and GGT in general chemistry and pH, pCO2 and pO2 in blood gas. Compared with the previous year (2003), the methods of analysis are not changed much and the coefficient of variation and VIS scores of general chemistry items are decreased.
Assuntos
Bilirrubina , Cálcio , Química , Química Clínica , Colesterol , Creatinina , Glucose , Concentração de Íons de Hidrogênio , Coreia (Geográfico) , Fósforo , Potássio , Sódio , Triglicerídeos , Ácido ÚricoRESUMO
Three external quality assesment trials which composed of 16 control materials(12 chemical materials and four microscopic photographs of urinary sediment) for interlaboratory quality control assesment in urinalysis were performed with 446, participants, in each, in the year of 2004. The response rate were 93.4% (422/452), 91.7% (411/448) and 91.7% (410/447), in the first , the second and the third trials, in each. The test items include pH, glucose, protein, ketone, bilirubin, blood, urobilinogen, nitrite, leukocyte estrase, specific gravity and four microscopic photographs of urinary sediment. The survey results are summarized as follows: 1.The chemical quality control test in urinalysis revealed generally good concordance. 2.The percentage of using urinalysis analyzer was slightly increased as 87.9% and the distribution of using reagent strip was similar to the previous year. 3.The percentage of response rate of microscopic photographs of urinary sediment was 80.7% and the percentage of good performance of these tests ware 85.8% to 95.8%.
Assuntos
Bilirrubina , Equidae , Glucose , Concentração de Íons de Hidrogênio , Coreia (Geográfico) , Leucócitos , Controle de Qualidade , Fitas Reagentes , Gravidade Específica , Urinálise , UrobilinogênioRESUMO
BACKGROUND: In chronic renal failure (CRF) patients, iron deficiency is a common problem and a primary cause of resistance to recombinant human erythropoietin (rHuEPO) therapy. Serum ferritin and transferrin saturation (TS) are most commonly used parameters of iron status in CRF patients but may be influenced by the presence of inflammation and malnutrition. Recently soluble transfer-rin receptor (sTfR) has been advocated as a useful parameter of iron deficiency. We evaluated sTfR as an iron deficient marker in CRF patients. METHODS: Included in this study were 73 CRF patients, 30 uncomplicated iron deficiency anemia (IDA) patients, and 55 normal control. Serum sTfR, serum ferritin, TS, and complete blood count were measured. The CRF patients were classified as absolute iron deficient, functional iron deficient, non-iron deficient, and iron overload groups according to National Kidney Foundation Kidney Disease and Dialysis Outcome Quality Initiative (NKF-K/DOQI) guideline. RESULTS: The sTfR concentrations were significantly higher in uncomplicated IDA patients (3.9 +/-1.5 mg/L) and significantly lower in CRF patients (1.1 +/-0.4 mg/L) than in normal controls (1.4 +/-0.4mg/L). In uncomplicated IDA patients, sTfR was inversely correlated with MCV, MCH, and MCHC. In CRF patients, sTfR had a weak inverse correlation with TS and MCHC, but not significantly different between the four groups. The sTfR was not significantly different between the CRF patients with the normal CRP and those with an increased CRP. CONCLUSIONS: The sTfR is useful for diagnosis of uncomplicated IDA, but not for the detection of iron deficiency in CRF patients. Further studies are needed for the evaluation of sTfR as an erythro-poietic marker with rHuEPO therapy.
Assuntos
Humanos , Anemia Ferropriva , Contagem de Células Sanguíneas , Diagnóstico , Diálise , Eritropoetina , Ferritinas , Inflamação , Ferro , Sobrecarga de Ferro , Rim , Nefropatias , Falência Renal Crônica , Desnutrição , Receptores da Transferrina , TransferrinaRESUMO
Ten trials of external quality assessment for Clinical Chemistry in general chemistry and blood gas were performed in 2003. All the control materials were sent in specifically-made boxes at the same time. The response rates were 90.3% in general chemistry and 91.8% in blood gas. The items included sodium, potassium, chloride, BUN, glucose, calcium, phosphorus, uric acid, creatinine, bilirubin, total protein, albumin, total cholesterol, triglyceride, AST, ALT, ALP, LD and GGT in general chemistry and pH, pCO2 and pO2 in blood gas. Compared with the previous year (2002), the methods of analysis are not changed much and the coefficient of variation and VIS scores of general chemistry items are decreased.
Assuntos
Bilirrubina , Cálcio , Química , Química Clínica , Colesterol , Creatinina , Glucose , Concentração de Íons de Hidrogênio , Coreia (Geográfico) , Fósforo , Potássio , Sódio , Triglicerídeos , Ácido ÚricoRESUMO
Three external quality assesment trials which composed of 12 control materials(12 chemical materials) for interlaboratory quality control assesment in urinalysis were performed with 446, participants, in each, in the year of 2003. The response rate were 92.4% (414/448), 91.9% (419/456) and 91.3% (408/447), in the first, the second and the third trials, in each. The test items include pH, glucose, protein, ketone, bilirubin, blood, urobilinogen, nitrite, leukocyte estrase and specific gravity. The survey results are summarized as follows: 1. The chemical quality control test in urinalysis revealed generally good concordance. 2. The percentage of using urinalysis analyzer was slightly increased as 86.8% and the distribution of using reagent strip was similar to the previous year.
Assuntos
Bilirrubina , Equidae , Glucose , Concentração de Íons de Hidrogênio , Coreia (Geográfico) , Leucócitos , Controle de Qualidade , Fitas Reagentes , Gravidade Específica , Urinálise , UrobilinogênioRESUMO
Atypical chronic myelogenous leukemia (aCML) has dysplastic as well as proliferative features in most instance and rarely evolves to blast crisis, so it is considered as a distinct clinical entity to classical BCR-ABL (+) CML. We experienced a patient who are diagnosed aCML and transformed to myeloid blast crisis after 17 months. Monosomy 7 and deletion of 12p were found on conventional cytogenetics.
Assuntos
Humanos , Crise Blástica , Citogenética , Leucemia Mielogênica Crônica BCR-ABL Positiva , MonossomiaRESUMO
Ten trials of external quality assessment for Clinical Chemistry in general chemistry and blood gas were performed in 2002. All the control materials were sent in specially-made boxes at the same time. The response rates were 81.2% in general chemistry and 85.7% in blood gas. The items included sodium, potassium, chloride, BUN, glucose, calcium, phosphorus, uric acid, creatinine, bilirubin, total protein, albumin, total cholesterol, triglyceride, AST, ALT, ALP, LD and GGT in general chemistry and pH, pCO2 and pO2 in blood gas. Compared with the previous year(2001), the methods of analysis are not changed much and the coefficient of variation and VIS scores of general chemistry items show no significant change.
Assuntos
Bilirrubina , Cálcio , Química , Química Clínica , Colesterol , Creatinina , Glucose , Concentração de Íons de Hidrogênio , Coreia (Geográfico) , Fósforo , Potássio , Sódio , Triglicerídeos , Ácido ÚricoRESUMO
Three external quality assesment trials which composed of 12 control materials(12 chemical materials) for interlaboratory quality control assesment in urinalysis were performed with 446, participants, in each, in the year of 2002. The response rate were 91.5% (408/446), 90.8% (405/445) and 90.4% (403/446), in the first , the second and the third trials, in each. The test items include pH, glucose, protein, ketone, bilirubin, blood, urobilinogen, nitrite, leukocyte estrase and specific gravity. The survey results are summarized as follows: 1.The chemical quality control test in urinalysis revealed generally good concordance. 2.The percentage of using urinalysis analyzer was slightly decreased as 79.0% and the distribution of using reagent strip was similar to the previous year.